TriPAV
TriPAV, a high-frequency rheometer for inks, coatings, and biofluids.
A compact, high-performance rheometer that enables measurement conditions unattainable with conventional rheometers.
Frequency range from 1 to 10,000 Hz
Access the fast dynamic regimes of inks, inkjet inks, paints, and biofluids, which are inaccessible in conventional rotational rheology (max ~100 Hz).
1 mPa.s and above to cover very low-viscosity fluids
Compatible with samples starting at 1 Pa.s and provides usable results in less than 5 minutes.
Exclusive distributor
Rheonova is the exclusive distributor of the TriPAV in France (Trijet Limited).

High-frequency
rheology
Access high-frequency ranges to detect phenomena that are invisible in conventional rheology (such as the elastic behavior of inks during ejection and the rapid relaxation of polymers).
< 5 min to obtain results that are immediately actionable
Rapid analyses in less than 5 minutes to accelerate your development cycles.
With very
small volumes
< 0.1 ml,ideal for expensive samples or those available in limited quantities.
Sensitive
samples
Safe analysis of solvent-based inks, biofluids, and heat-sensitive formulations.
TriPAV applications: inkjet inks, coatings, pharmaceuticals and biofluids
The TriPAV is the gold standard instrument for characterizing high-frequency rheology, particularly well-suited for environments where rapid fluid dynamics are critical.
Ink formulators
Optimize your formulations by selecting the right additives and resins to ensure stability, ejection reliability, and compatibility with your printheads.
Printhead manufacturers and system integrators
Analyze and optimize waveform characteristics to predict and control ink ejection behavior.
Chemical manufacturers
Formulate and characterize additives and resins to meet the viscoelastic requirements of inkjet applications.
Coating formulators
Adjust the rheological properties of your paints and enamels to make them compatible with inkjet processes.
Pharmaceutical and biomedical companies
Analyze your biofluids to improve the understanding, stability, and performance of your formulations.
Shaping
rheology solutions
Request a TriPAV Demo

TriPAV technical specifications
| Features | Specifications | |
|---|---|---|
| Rheometer type | High-frequency solid-state rheometer requiring little or no maintenance or annual calibration | |
| Frequency range | 1 Hz to 10,000 Hz | |
| Temperature range | 5 °C to 80 °C | |
| Viscosity range | 1 mPa.s and above | |
| Sample required | < 0.1 ml. Sample thickness: 10 µm to 1 mm - depending on the viscosity of the sample and the required frequency range | |
| Dimensions | Main unit including heating/cooling jacket: 8 cm x 9 cm x 10 cm | |
| High-frequency testing | Sweep from 1 Hz to 10,000 Hz, < 5 minutes |
De l’analyse à la performance, notre approche transforme vos défis rhéologiques en résultats concrets
FAQ - TriPAV
What is the difference between the TriPAV and a conventional rotational rheometer?
A rotational rheometer operates at frequencies up to ~100 Hz. The TriPAV reaches up to 10,000 Hz, allowing for the measurement of viscoelastic properties (G', G'', tan delta) under fast dynamic conditions representative of inkjet, spraying, and ejection processes.
Is the TriPAV compatible with solvent-based inks or sensitive biofluids?
Yes, the TriPAV is compatible with solvent-based inks thanks to its hermetically sealed design, which prevents evaporation, and with sensitive biofluids thanks to its micro-rheological mode, which operates at extremely low strain levels that preserve the integrity of fragile samples.
Can the viscosity of very low-viscosity fluids, such as inkjet inks, be measured?
Yes. The TriPAV is compatible with viscosities as low as 1 mPa.s, making it suitable for aqueous and solvent-based inkjet inks, solvents, and aqueous biofluids.
Do you offer a demonstration using my own samples?
Yes. Rheonova offers demonstrations using your own samples, either on-site or in the lab. Contact us to schedule a session.